Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 127(1): 161-167, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33218745

RESUMO

STATEMENT OF PROBLEM: How the loading rate might affect the mechanical properties of interim materials and interim fixed dental prostheses is unclear. PURPOSE: The purpose of this in vitro study was to compare the material stiffness, material strength, and structural strength of interim 3-unit fixed dental prostheses fabricated from 3 interim materials when stressed at different loading rates. MATERIAL AND METHODS: Bar-shaped specimens and anatomically correct interim 3-unit fixed dental prostheses with a modified-ridge lap pontic were fabricated from polyethyl methacrylate resin (Trim) and 2 bis-acrylic composite resins (TempSmart; Integrity) (n=10). Flexural modulus and strength of the bar specimens, representing material stiffness and strength, were determined with a 4-point bend test in a universal testing machine. The structural strength of the prosthesis was assessed from the failure load from a vertical force applied on the occlusal surface of the pontic. Three loading rates, 0.5, 5, or 10 mm/min, were evaluated. Results were statistically analyzed with 2-way analysis of variance and multiple comparisons (α=.05). RESULTS: Loading rate and material significantly affected flexural modulus, flexural strength, and structural strength (P<.05). Increasing loading rate significantly increased the flexural modulus of all materials (P<.05), but the effect of loading rate on the flexural strength of bis-acrylic composite resins was mostly insignificant. Polyethyl methacrylate specimens did not fracture when loaded at 0.5 or 5 mm/min, and the interim fixed dental prostheses made from polyethyl methacrylate did not fracture at the 0.5 mm/min loading rate. Dual-polymerizing bis-acrylic composite resin had significantly higher flexural modulus and strengths than autopolymerizing bis-acrylic composite resin. CONCLUSIONS: Polyethyl methacrylate resin had the lowest stiffness among the interim materials tested and did not fracture but excessively deformed at the low loading rate. Dual-polymerizing bis-acrylic composite resin consistently had higher stiffness and material strength and provided higher structural strength than the autopolymerizing bis-acrylic composite resin. Loading rate significantly affected the mechanical properties of polyethyl methacrylate resin (P<.05), but the effect was indistinct for the bis-acrylic materials.


Assuntos
Materiais Dentários , Prótese Parcial Temporária , Resinas Compostas , Análise do Estresse Dentário , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície
2.
J Prosthet Dent ; 127(2): 275.e1-275.e7, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34895902

RESUMO

STATEMENT OF PROBLEM: New techniques and materials for the laboratory fabrication of interim fixed dental prostheses have gained in popularity, yet how their failure strengths compare with conventional chairside materials is unclear. PURPOSE: The purpose of this in vitro study was to compare the strength of computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethylmethacrylate (PMMA) or 3-dimensionally (3D) printed bis-acryl interim fixed dental prostheses with a traditional chairside-dispensed autopolymerizing bis-acryl prosthesis while taking into account the effect of loading rate and storage time. MATERIAL AND METHODS: A dentiform mandibular second premolar and second molar with a first molar pontic were prepared and scanned. Three groups of 3-unit interim fixed dental prostheses were fabricated: milled PMMA, 3D-printed bis-acryl, and chairside-dispensed autopolymerizing bis-acryl. The interim prostheses were evaluated for fit with a silicone disclosing material and cemented onto 3D-printed resin dies. The specimens were stored in 100% humidity at 37 °C. After 1 or 30 days of storage, the cemented interim prostheses were loaded to failure in a universal testing machine at 1 or 10 mm/min (n=15/group). Failure loads were analyzed by 3-way analysis of variance and multiple comparisons (α=.05). RESULTS: Mean ±standard deviation failure loads ranged from 363 ±93 N (3D-printed bis-acryl, 30 days, 1 mm/min) to 729 ±113 N (milled PMMA, 24 hours, 1 mm/min). Loading rate did not significantly affect failure load of the interim prostheses (P=.306). After 30 days of storage in 100% humidity, the failure load of milled PMMA and 3D-printed bis-acryl interim prostheses decreased significantly, but the chairside autopolymerizing bis-acryl prostheses were not affected. After 30 days of storage, the failure loads of milled PMMA and chairside autopolymerizing bis-acryl were not significantly different. CONCLUSIONS: Regardless of loading rate, interim fixed dental prostheses from milled PMMA had the highest initial strength 1 day after storage. Thirty days of exposure to humidity, however, reduced the strength of the CAD-CAM-manufactured interim prostheses, whereas the traditional chairside prostheses retained their strength.


Assuntos
Desenho Assistido por Computador , Prótese Parcial Temporária , Análise do Estresse Dentário , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
3.
Compend Contin Educ Dent ; 42(4): e1-e4, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34469177

RESUMO

The wear of dentures carries with it the possibility of an inflammatory response by the denture-bearing tissues. Lack of or improper hygiene has been shown to contribute to denture stomatitis (DS). Although essential, denture hygiene is often overlooked by patients or performed improperly. As professional caregivers dentists must instruct patients and ensure that they understand the relevance and importance of denture hygiene. In light of this, the authors conducted a critical review of the literature on protocols and procedures to highlight the importance of denture hygiene and clinically show the effects of lack of denture care. A literature search was done through Google, PubMed, and Google Scholar that focused on publications published in English that dealt with denture hygiene and the disinfection process and on the protocols used. Relevant articles for protocols for denture disinfections were reviewed, and the results of different disinfection techniques were assessed, including manual, chemical, microwave, and a combination of techniques. The authors conclude that dentists must take time to instruct patients on proper denture disinfection procedures and the importance of cleaning the dentures well at least once daily. Denture hygiene and removal prior to sleeping is beneficial in preventing DS and allowing the tissue to achieve a state of homeostasis.


Assuntos
Estomatite sob Prótese , Dentaduras , Desinfecção , Humanos , Higiene , Higiene Bucal , Estomatite sob Prótese/etiologia
4.
J Prosthodont ; 30(3): 245-251, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32869384

RESUMO

PURPOSE: To determine the efficacy of various finishing and polishing techniques on the surface roughness of two computer-aided design/computer-aided manufacturing (CAD/CAM) materials, lithium disilicate (IPS e.max), lithium disilicate reinforced with lithium aluminosilicate (Straumann® n!ce™), and a stackable low-fusing nanofluorapatite glass ceramic (Ceram). MATERIALS AND METHODS: Flat specimens (n = 12) per treatment group were fabricated 2 mm thick, 15 mm in length, and 12mm in width. Samples were either glazed or polished. Glazing was accomplished with either Ivoclar IPS e.max CAD crystall glaze spray or IPS e.max Ceram glaze paste, according to manufacturer instructions. Three different polishing systems were tested: Brasseler Dialite HP, Ivoclar OptraFine, and Komet LD/ZR. Polishing was performed using a Kavo adjustable slow speed electric contra-angle handpiece mounted to an oscillating Toothbrush Dentifrice Assessment Instrument. Surface roughness data was collected using a benchtop stylus profilometer and analyzed for statistical significance using two-way ANOVA (α = 0.05). Representative scanning electron micrograph images were generated for all samples. RESULTS: Overall there was no significant difference in Ra when comparing types of ceramic (p = 0.9315, F = 0.071). However, there was a statistically significant difference when comparing groups of finishing treatments (p < 0.001, F = 113.5) and also when comparing finishing treatment with ceramic type (p < 0.001, F = 11.13). No significant difference was found with IPS e.max CAD crystall glaze spray on Straumann® n!ce™ versus IPS e.max Ceram glaze paste on IPS e.max Ceram (p = 0.8745) or IPS e.max CAD crystall glaze spray on IPS e.max versus IPS e.max Ceram glaze paste on IPS e.max Ceram (p = 0.3373). Significant differences in Ra of Straumann® n!ce™ were found when comparing Brasseler with Ivoclar (p = 0.0014) and Ivoclar with Komet (p = 0.047). No significant difference was observed between Brasseler and Komet (p = 0.8099). CONCLUSIONS: It appears that the degree of surface roughness depends upon the specific finishing system and ceramic combination used. Straumann® n!ce™ is more efficiently polished using Brasseler Dialite HP or Komet LD/ZR polishing systems. Ivoclar crystal glaze spray was found to be equally as effective on Straumann® n!ce™ and IPS e.max as IPS e.max Ceram glaze paste on IPS e.max Ceram.


Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Polimento Dentário , Teste de Materiais , Polônia , Propriedades de Superfície
5.
J Prosthet Dent ; 120(1): 123-131, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29429839

RESUMO

STATEMENT OF PROBLEM: Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. PURPOSE: The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. MATERIAL AND METHODS: Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were used. RESULTS: Changing the number and the location of anatomic landmarks had a small effect on the precision of the surface fitting. Repeated scans yielded high precision levels. In contrast, intraobserver repeatability had a larger error. In general, injection-molded dentures showed less displacement after polymerization than did the compression-molded ones. These differences were more substantial at the denture tooth level than on the intaglio surfaces. CONCLUSIONS: Anatomic noninvasive fiducials chosen at distinct locations of maxillary edentulous areas seem to be reliable markers for the superposition of corresponding digital surface scans. Maxillary dentures processed with the injection molding technique have minimal deformation. Posterior denture teeth displace in 3 dimensions with the compression molding technique.


Assuntos
Pontos de Referência Anatômicos , Encaixe de Precisão de Dentadura , Prótese Total Superior , Processamento de Imagem Assistida por Computador/métodos , Maxila/anatomia & histologia , Bases de Dentadura , Humanos , Técnicas In Vitro , Software , Propriedades de Superfície , Dimensão Vertical
6.
J Dent Educ ; 80(12): 1457-1463, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27934671

RESUMO

Preclinical dental students must demonstrate aptitude in the preparation of teeth for treatment with several types of fixed dental prostheses. The optimal sequence of instruction and examination of these crown preparations in preclinical fixed prosthodontics is unknown. The aim of this study was to determine if grading scores by faculty and students were affected by changing the sequence of crown type preparations. Practical exams of two successive student cohorts (n=89 in 2014; n=92 in 2015) at one U.S. dental school using three crown preparations (full cast, porcelain fused to metal, and all-ceramic) in different order were analyzed by faculty grades and student self-assessment. All of the models indicated that the sequence in which the crown type preparations were taught did have an effect on the grades. The 2014 cohort had overall higher grades and particularly higher grades for the all-ceramic crown preparations. Evaluation scores were affected by the sequence in which the different crown type preparations were taught and tested. Although the overall results suggested that students may perform better if the all-ceramic crown preparation is taught last, this tendency may differ between years.


Assuntos
Competência Clínica , Coroas , Educação em Odontologia/métodos , Prostodontia/educação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...